Systema Triphasicum Omnino-in-Uno Accumulationis Energiae SUN8000T-E/A
(Euro-Norma)
Systema accumulationis energiae domesticae ROYPOW omnia in uno inversorem triphasicum summae efficacitatis et batterias LFP tutas et diuturnas coniungit. Fruere vita viridi cum potentia continua, efficacia energiae aucta, et sumptibus electricitatis imminutis, quo facto domus tua etiam inter interruptiones vel temporibus maximae postulationis potentiam retineat.
CE, VDE-AR-E 2510-50, EN IEC 62619, EN IEC 62477, EN IEC62040, RCM, CEC, UN38.3
Optimizator Batteriae
RMH95050
Ambitus Tensionis (V)
550-950
Maxima Currens Onus/Exonerationis (A)
27
Communicatio
CAN, RS485
Scalabilitas
Maxime quattuor in parallelo
Dimensiones (L × P × A, mm)
650 × 265 × 270
Pondus (kg)
15
Specificatio Invertoris Hybridi
ModellumSUN8OOOT-E/I
Ingressus-DC (PV)
Potentia Maxima (Wp)
Viginti milia
Maxima Tensio DC (V)
mille
MPPT Tensio (V)
CLX ~ CMCL
MPPT Tensio (V, plena onere)
200 ~ 850
Tensio Initialis (V)
CLXXX
Maxima Currens Ingressa (A)
XXX / XX
Maxima Brevis Currens (A)
XL / XXX
Numerus MPPT
2
Numerus Filorum per MPPT
2-1
Ingressus-DC (Batteria)
Batteria Compatibilis
Systema Accumulatorum RBmax MH
Ambitus Tensionis (V)
550 – 950
Maxima Potentia Impletionis/Exonerationis (W)
11000 / 8800
Maxima Currens Impletionis/Exonerationis (A)
XX / XVI
AC (in reti)
Potentia Producta Aestimata (W)
Octo milia
Potentia Apparens Maxima Emissa (VA)
8800
Potentia Emissa Maxima (W)
8800
Potentia Apparens Ingressa Aestimata (VA)
22500
Maxima Currens Ingressa (A)
32
Tensio retiaria aestimata (V)
380 / 400, 3W+N
Frequentia Retis Aestimata (Hz)
50 / 60
Maxima Currens Egressus (A)
3 * 12.8
THDI (potentia aestimata)
< 3%
Factor Potentiae
~1 (Adaptabilis a 0.8 ductiva ad 0.8 tardatam)
ModellumSUN8OOOT-E/I
AC (Subsidiaria)
Potentia Producta Aestimata (W)
Octo milia
Currens Egressus Aestimatus (A)
3 * 12.8
Potentia Deviationis Aestimata (VA)
22500
Currens Deviationis Aestimatus (A)
32
Tensio Egressus Aestimata (V)
380 / 400, 3W+N
Frequentia Aestimata (Hz)
50 / 60
THDV (onus lineare)
< 2%
Capacitas Oneris Superflui
120% per 10 minuta, 200% per 10 secunda
THDV
< 2 (onus R), < 5 (onus RCD)
Scalabilitas
Maxime sex in parallelo
Efficacia
Efficacia Maxima
98.0%
Euro.Efficacia
97.3%
Maxima Efficacia Oneris (PV ad Bus)
99%
Maxima Efficacia Oneris/Exonerationis (a Rete ad Bus)
99%
Protectio